Make sure Nitrates are not present in your pool. Page Chlorine Testing Chlorine Testing It is recommended that chlorine test samples be taken from two places. Compare the samples. A higher level should be found at the pool return line. The higher level at the pool return line indicates IntelliChlor is producing chlorine. Switch on the pump to circulate the pool water. Page 21 Table 2. The Stabilizer reading should be maintained at 75 PPM. Page Section 4: Installation This section describes how to install the IntelliChlor electrolytic cell assembly into the pool plumbing system.

Also, included are connection instructions for IntelliTouch and EasyTouch systems. Before installing, review the IntelliChlor kit contents and required tools. For more information see plumbing diagrams on page 3 and 4. An alternate connection can be made by splicing anywhere along the four wire connection that connects the IntelliTouch or EasyTouch indoor control panel to the load center.

Page Section 5: Troubleshooting Use the following troubleshooting information to resolve possible problems with the IntelliChlor system. Note: Switch power off to unit before to attempting service or repair.

Page 31 Pentair Water is not, however, responsible under this warranty for any cost of shipping or transportation of the equipment or parts thereof to or from the Technical Service Department.

Also, Pentair Water is not liable for any loss of time, inconvenience, incidental expenses such as telephone calls, labor or material charges incurred in connection with the removal or replacement of the equipment, or any other incidental or consequential damages. Print page 1 Print document 32 pages.

Rename the bookmark. Delete bookmark? Cancel Delete. Delete from my manuals? IntelliChlor models Electrolytic Cell Controller IntelliChlor Power Center System Diagram Loop Plumbing Diagram IntelliChlor Plumbing Diagram Section 1: IntelliChlor Control Panel Status LEDs More and Less Output Buttons Self Cleaning reverse Section 2: Operating IntelliChlor Initial Startup Period Startup Procedure Super Chlorination Apply power Operating in winter General Cautions Section 3: User Maintenance Daily service Weekly service.

Monthly Service Cell Usage Hours Meter Electrolytic Cell Cleaning Chemistry You Need to Know Optimum Pool Water Conditions Chlorine Testing What Type of Salt to Use How Much Salt to Use? How to Add Salt to the Pool Pool Water Preparation IntelliChlor Pass-Through Cell Selecting Model Size Section 4: Installation Kit Contents Required Tools Installing the Cell Assembly Section 5: Troubleshooting Table 1:Troubleshooting IntelliChlor UL approved four conductor gauge cable for connection to the Power Center.

At each of those times, the salt level LED indicator lights flash in a scrolling sequence for two 2 minutes to indicate that the IECG is in analysis mode. After two 2 minutes, the LED indicators lights will signal one 1 of four 4 salinity ranges. The power supply is connected with the pool circulation pump electrical source so that the IECG only operates when the pool pump is on. A fuse holder is mounted on the bottom of the Power Center for additional protection.

There are no other controls or lights on the Power Center. The following schematic diagram shows a typical IntelliChlor system installation. It is recommended that a 2 inch check valve be installed between the input side of the IntelliChlor Electronic Chlorine Generator and the main heater output pipe, as shown below.

Note: This schematic diagram is not drawn to scale. The IntelliChlor Electronic Chlorine Generator is designed to operate with water flow rates from 20 gallons per minute gpm up to gpm. Do not exceed gpm or pipe manufacturers recommended flow rate, whichever is less. For flow rates over 80 gpm, it is recommend that you use a bypass loop as shown below for best chlorine production. Installations with flow rates over 80 gallons per minute are those that have in-floor cleaning systems or booster pumps.

These systems should use a bypass loop with the IECG with a flow control valve that assures that the flow through the IECG is maintained within its designed operating water flow rates.

The ICEG should be no closer than three 3 feet away from the heater outlet. The IECG salt level checks the pool water daily and displays the levels as follows:. The pool water salt level is between ppm and , and the IECG is producing chlorine. Flashing green LED: Salt level is above ppm. Chlorine is being produced but the salt level is too high which increases the risk of corrosion and deterioration of pool equipment and surfaces in and around the pool.

Pool water needs to be drained and refilled one 1 foot at a time until the salt level is lowered to ppm. The pool water salt level is between ppm and ppm. The salt level should be independently checked and salt added to the pool water if necessary to obtain a salt level of - ppm. The cell will continue to produce chlorine but will be at a reduced level.

The water salt level has fallen below ppm. The IECG will not produce chlorine until additional salt is added. Service is needed. Chlorine is not being produced. The blades may have calcium buildup.

The IECG is not producing chlorine. It may be in an off-period of the sanitizing cycle and will return on shortly. Life : The IECG is designed to produce chlorine for approximately 10, hours of proper use approximately five. The IECG is good. Welcome to ManualMachine. We have sent a verification link to to complete your registration. Log In Sign Up. Forgot password? Enter your email address and check your inbox. Please check your email for further instructions. Enter a new password. All rights reserved This document is subject to change without notice Hawkins Ave.

Eastern Time Moorpark, California 8 A. Pacific Time Phone: Fax: Web sites visit www. Note: If the Cell green LED is flashing with the Check Salt LED, it indicates the salt level in the pool needs to be checked, adding if necessary, and the cell needs to be inspected and cleaned if necessary.

Life : The IECG is designed to produce chlorine for approximately 10, hours of proper use approximately five 5 years of average use before replacement is needed. You can only view or download manuals with. Sign Up and get 5 for free. Upload your files to the site.